Skip to content

Reference guide · Rafter lengths, cuts and birdsmouth

Rafter length and pitch table

By the Mirage Interactive team · Last checked

The length of a common rafter follows from the roof's pitch (written as rise in 12, such as 6/12) and its run, the horizontal distance from the outer wall to the centre of the ridge. The table gives the length per foot of run for each pitch; multiply by the run in feet.

The plumb cut is the angle at the top of the rafter where it meets the ridge, and the level cut (the seat cut) is the angle where it sits on the wall plate. Both are measured from the framing square.

Printable table

Rafter length per 12 inches of run, with the roof angle and the cut angles, for the usual pitches. Regular roof, no overhang. Use your browser's print command to print this page: the tables print without the navigation.

Rafter length per foot of run, and cut angles, by roof pitch (regular roof, no overhang)
Pitch (rise in 12)Roof angle (deg)Slope (%)Rafter length per 12 in of run (in)Plumb cut (deg)Level (seat) cut (deg)
2/129.4616.712.1669.4680.54
3/1214.0425.012.36914.0475.96
4/1218.4333.312.64918.4371.57
5/1222.6241.713.00022.6267.38
6/1226.5750.013.41626.5763.43
7/1230.2658.313.89230.2659.74
8/1233.6966.714.42233.6956.31
9/1236.8775.015.00036.8753.13
10/1239.8183.315.62039.8150.19
12/1245.00100.016.97145.0045.00

Source: The Roof Framing app's reference calculator (common rafter); the roof angles are re-checked against every rise-in-12 case in the app's pitch tests.

Formulas

Roof angle
angle = arctan( rise per 12 / 12 )
Common rafter length
length = run x square root of (1 + (rise per 12 / 12) squared)
This is the theoretical length along the top edge, between plumb lines, before the ridge deduction and the tail.
Ridge deduction
deduction = half the ridge board thickness x length factor
The half thickness is a horizontal distance, so it is multiplied by the length factor, the square root of (1 + (rise per 12 / 12) squared), to follow the slope. The length to the ridge face is the theoretical length less the deduction. Some printed guides subtract the half thickness along the rafter instead, which is slightly less.

Worked example

A 4/12 roof with a 10 ft run

  1. Pitch 4/12: slope 4 / 12 = 0.3333, roof angle 18.435 degrees.
  2. Run 3,048 mm (10 ft): rise = 1016 mm (40.0 in).
  3. Rafter length = 3,048 x square root of (1 + 0.3333 squared) = 3212.9 mm = 126.49 in, which is 10.54 ft.
  4. Plumb cut 18.43 degrees and level cut 71.57 degrees from the square. Hip and valley rafters of a regular roof are longer again: the hip run is the common run times 1.4142.

Things to watch

  • The table gives the theoretical length. For a real rafter add the tail (overhang along the rafter) and subtract the ridge deduction.
  • A seat (birdsmouth) cut removes wood where the rafter sits on the plate. Check your local code for notch limits.

Related guide: Hip rafter calculator: length formula and cuts · Birdsmouth cut depth calculator: seat, heel and share of the rafter · Rafter length calculator with overhang and ridge board · Shed roof rafter length calculator: rise, run and rafter length

Skip the arithmetic

Roof Framing Calculator & Cuts

Common, hip, valley and jack rafter lengths, plumb and level cuts, side cuts and birdsmouth, from the pitch and run. One-time purchase · No subscription · Price shown in your store. Works offline, no ads, no account.

Questions

How do I calculate rafter length from pitch?

Multiply the run by the square root of 1 plus the square of the slope, where the slope is the rise per 12 divided by 12. The table gives the result per foot of run.

What is the angle of a 6/12 roof?

About 26.57 degrees, with a rafter length of 13.416 inches per 12 inches of run.