The length of a common rafter has three parts: the part from the wall to the ridge, a deduction because the rafter stops at the face of the ridge board and not at its centre, and the tail that overhangs the wall. Each part starts as a horizontal distance that has to be lengthened to follow the slope.

This guide gives all three by pitch, so you can build the number up the way you would on the job: run times the length factor, less the ridge deduction, plus the tail. All lengths are along the top edge of the rafter, between plumb lines.

The short answer

Length factor k = square root of (1 + (pitch / 12) squared). Overall length = (run - half the ridge thickness + overhang) x k, where run, ridge thickness and overhang are horizontal distances in the same unit.

For a 6/12 roof the factor is 1.1180. A 12 ft run, a 1 1/2 inch ridge board and a 12 inch overhang give 173.57 inches along the top edge (173 9/16).

Tables

The first table gives the roof angle and length factor, the tail length for a 12 inch horizontal overhang and the ridge deduction for a 1 1/2 inch ridge board, by pitch. The second gives the overall rafter length for common runs with a 12 inch overhang and a 1 1/2 inch ridge board. Use your browser's print command to print this page: the tables print without the navigation.

Side view. Run and overhang are horizontal; the length along the rafter is each of them times the length factor k, less the ridge deduction.
Length factor, tail for a 12 inch overhang and ridge deduction for a 1 1/2 inch ridge board, by pitch, in inches
Pitch (rise in 12)Roof angle (deg)Length factor kTail for 12 in overhang (in)Ridge deduction, 1 1/2 in ridge (in)
3/1214.041.030812.369 (12 3/8)0.773
4/1218.431.054112.649 (12 5/8)0.791
5/1222.621.083313.000 (13)0.813
6/1226.571.118013.416 (13 7/16)0.839
7/1230.261.157713.892 (13 7/8)0.868
8/1233.691.201914.422 (14 7/16)0.901
9/1236.871.250015.000 (15)0.938
10/1239.811.301715.620 (15 5/8)0.976
11/1242.511.356616.279 (16 1/4)1.017
12/1245.001.414216.971 (17)1.061

Source: computed by the site build from the formulas below.

Overall rafter length in inches, long point to long point, by run, with a 12 inch overhang and a 1 1/2 inch ridge board
Run (ft)4/12 overall (in)6/12 overall (in)8/12 overall (in)
8113.05 (113 1/16)119.91 (119 15/16)128.90 (128 7/8)
10138.35 (138 3/8)146.74 (146 3/4)157.74 (157 3/4)
12163.65 (163 5/8)173.57 (173 9/16)186.59 (186 9/16)
14188.95 (188 15/16)200.41 (200 7/16)215.43 (215 7/16)
16214.24 (214 1/4)227.24 (227 1/4)244.28 (244 1/4)

Source: computed by the site build from the formulas below.

Formulas

Length factor and angle
k = square root of (1 + (pitch / 12)^2) angle = arctan(pitch / 12)
A run of 12 inches gives 12 x k inches along the slope.
Ridge deduction
deduction = (ridge thickness / 2) x k
The ridge board has a vertical face, so its half thickness is a horizontal distance and is lengthened by k to follow the slope. Some printed guides take the half thickness along the rafter instead: for a 1 1/2 inch ridge at 6/12 that is 0.75 inch against 0.8385 inch.
Tail and overall length
tail = overhang x k overall = run x k - deduction + tail
The overhang is measured horizontally from the outside face of the wall plate to the plumb cut at the end of the tail. Fascia, soffit and any tail pattern are not included.

Worked example

A 6/12 roof, 12 ft run, 1 1/2 inch ridge board, 12 inch overhang

  1. Run 12 ft = 144 inches and the rise is 144 x 6 / 12 = 72 inches. k = square root of (1 + 0.5 squared) = 1.118034 and the roof angle is 26.565 degrees.
  2. Theoretical length = 144 x 1.118034 = 160.997 inches (13 ft 5 inches): the top-edge length from the plumb line at the wall to the plumb line at the ridge centre.
  3. Ridge deduction = 0.75 x 1.118034 = 0.8385 inch, so the length to the ridge face is 160.158 inches. Taking 0.75 inch along the rafter from 161 inches would give 160 1/4 inches, about 0.09 inch more.
  4. Tail = 12 x 1.118034 = 13.416 inches. Overall length = 160.158 + 13.416 = 173.575 inches (173 9/16), long point to long point.
  5. The plumb cut is 26.57 degrees from square and the level (seat) cut is 63.43 degrees from square.

Things to watch

  • The overhang here is horizontal. If your plan gives the overhang along the rafter, divide it by k to get the horizontal figure first.
  • The birdsmouth and the depth of the rafter change where you mark the cuts, not these lengths. The birdsmouth guide covers the notch.
  • This is geometry only. It does not check spans, member sizes, loads or code. Cut the first rafter, try it in place and use it as the pattern for the rest.

Related guide: Rafter length and pitch table

More from this family: Hip rafter calculator: length formula and cuts · Birdsmouth cut depth calculator: seat, heel and share of the rafter · Shed roof rafter length calculator: rise, run and rafter length

Skip the arithmetic

Roof Framing Calculator & Cuts

Roof Framing Calculator & Cuts gives the length along the top edge, plumb, level and seat cuts, birdsmouth and tail of a common rafter from the pitch and run, with the ridge board thickness and overhang you type. One-time purchase · No subscription · Price shown in your store. Works offline, no ads, no account.

Questions

How do I add an overhang to a rafter length?

Multiply the horizontal overhang by the length factor and add it to the length from the wall to the ridge. A 12 inch overhang adds 13.4 inches at 6/12.

Is the overhang measured along the rafter or level?

Level, from the outside face of the wall plate. Multiply by the length factor to get the length along the rafter.

How much do I deduct for the ridge board?

Half the ridge thickness times the length factor. A 1 1/2 inch ridge at 6/12 deducts 0.84 inch.