Reference guide · Rafter lengths, cuts and birdsmouth
Birdsmouth cut depth calculator: seat, heel and share of the rafter
By the Mirage Interactive team · Last checked
A birdsmouth is the notch at the foot of a rafter. It has a level seat that sits on the top of the wall plate and a plumb heel cut that rises from the seat to the edge. The width of the seat is set by the bearing you want on the plate. The depth of the cut then follows from the pitch: the steeper the roof, the deeper the heel for the same seat.
Depth matters because the notch removes wood from the rafter at the point where it carries load. This guide gives the geometry: how long the heel cut is, how deep the notch goes measured square to the rafter edge, and what share of the rafter depth that is. It does not tell you how deep a notch may be, which is set by the building code you work under and by where the notch is.
The short answer
Heel cut length = seat width x pitch / 12, measured along the plumb cut. Notch depth square to the rafter edge = seat width x sin(roof angle).
For a 3 1/2 inch seat on a 6/12 roof the heel cut is 1.75 inches (1 3/4) and the notch depth is 1.57 inches, which is 21.6 percent of a 2x8 rafter.
Tables
The first table gives the heel length and the notch depth for a 3 1/2 inch seat (a 2x4 wall plate) and a 5 1/2 inch seat (a 2x6), by pitch. The second table gives the notch depth for a 3 1/2 inch seat as a percentage of the rafter depth, for the actual depths of 2x6 to 2x12 rafters. Use your browser's print command to print this page: the tables print without the navigation.
| Pitch (rise in 12) | Roof angle (deg) | 3 1/2 in seat: heel cut | 3 1/2 in seat: notch depth | 5 1/2 in seat: heel cut | 5 1/2 in seat: notch depth |
|---|---|---|---|---|---|
| 3 | 14.04 | 0.88 (7/8) | 0.85 | 1.38 (1 3/8) | 1.33 |
| 4 | 18.43 | 1.17 (1 3/16) | 1.11 | 1.83 (1 13/16) | 1.74 |
| 5 | 22.62 | 1.46 (1 7/16) | 1.35 | 2.29 (2 5/16) | 2.12 |
| 6 | 26.57 | 1.75 (1 3/4) | 1.57 | 2.75 (2 3/4) | 2.46 |
| 7 | 30.26 | 2.04 (2 1/16) | 1.76 | 3.21 (3 3/16) | 2.77 |
| 8 | 33.69 | 2.33 (2 5/16) | 1.94 | 3.67 (3 11/16) | 3.05 |
| 9 | 36.87 | 2.63 (2 5/8) | 2.10 | 4.13 (4 1/8) | 3.30 |
| 10 | 39.81 | 2.92 (2 15/16) | 2.24 | 4.58 (4 9/16) | 3.52 |
| 11 | 42.51 | 3.21 (3 3/16) | 2.37 | 5.04 (5 1/16) | 3.72 |
| 12 | 45.00 | 3.50 (3 1/2) | 2.47 | 5.50 (5 1/2) | 3.89 |
Source: computed by the site build from the formulas below.
| Pitch (rise in 12) | 5 1/2 in (2x6) | 7 1/4 in (2x8) | 9 1/4 in (2x10) | 11 1/4 in (2x12) |
|---|---|---|---|---|
| 3 | 15.4 | 11.7 | 9.2 | 7.5 |
| 4 | 20.1 | 15.3 | 12.0 | 9.8 |
| 5 | 24.5 | 18.6 | 14.6 | 12.0 |
| 6 | 28.5 | 21.6 | 16.9 | 13.9 |
| 7 | 32.1 | 24.3 | 19.1 | 15.7 |
| 8 | 35.3 | 26.8 | 21.0 | 17.3 |
| 9 | 38.2 | 29.0 | 22.7 | 18.7 |
| 10 | 40.7 | 30.9 | 24.2 | 19.9 |
| 11 | 43.0 | 32.6 | 25.6 | 21.0 |
| 12 | 45.0 | 34.1 | 26.8 | 22.0 |
Source: computed by the site build from the formulas below.
Formulas
- Roof angle
- angle = arctan( pitch / 12 )
- Pitch is the rise per 12 of horizontal run.
- Heel cut length
- heel = seat x pitch / 12
- Measured along the plumb cut, from the inside corner of the notch to the lower edge of the rafter.
- Notch depth
- notch = seat x sin(angle) share = 100 x notch / rafter depth
- The notch depth is the distance from the inside corner of the notch to the lower edge of the rafter, measured square to that edge. Rafter depth is the actual depth: 7 1/4 inches for a 2x8.
Worked example
A 3 1/2 inch seat on a 6/12 roof, 2x8 rafters
- The roof angle is arctan( 6 / 12 ) = 26.57 degrees.
- The heel cut is 3.5 x 6 / 12 = 1.75 inches (1 3/4), measured along the plumb cut.
- The notch depth is 3.5 x sin 26.57 = 1.57 inches, square to the rafter edge.
- A 2x8 rafter is 7.25 inches deep, so the notch removes 21.6 percent of it.
- Compare that figure with the limit in your building code or the engineer's drawings for your rafter. Both vary by place, by member and by where the notch is.
Things to watch
- This page does not say how deep a notch is allowed to be. Limits depend on the code you work under, the rafter and the position of the notch, and an engineer or the local building department decides them.
- The seat width is the bearing on the plate, not the width of the plate. Measure the plate and decide the bearing before you mark the cut.
- Mark the plumb and seat cuts from the layout line of the rafter, and try the cut on a scrap piece first. Cut slightly inside the line and trim to fit.
Related guide: Rafter length and pitch table
More from this family: Hip rafter calculator: length formula and cuts · Rafter length calculator with overhang and ridge board · Shed roof rafter length calculator: rise, run and rafter length
Skip the arithmetic
Roof Framing Calculator & Cuts
Roof Framing Calculator & Cuts gives the length, plumb, level and seat cuts of a common rafter, with the birdsmouth and tail, from the pitch and run. One-time purchase · No subscription · Price shown in your store. Works offline, no ads, no account.
Questions
How deep should a birdsmouth cut be?
The geometry gives the depth for a seat width and a pitch, as in the table. How much depth is allowed is set by the building code you work under and the position of the notch, so check them for your job.
What is the heel cut length of a birdsmouth?
The seat width times the pitch divided by 12, along the plumb cut. A 3 1/2 inch seat on a 6/12 roof gives 1 3/4 inches.
Does a steeper roof need a deeper cut?
For the same seat width, yes. The notch depth grows with the sine of the roof angle, so the steeper roof removes more of the rafter.